General Information
NimbleGen Sequence Capture Arrays offer a highly flexible and cost-effective approach to specifically capture up to 30 Mb of genomic sequence. The production of custom arrays (385K and 2.1M features) as well as the catalogue Human Exome Array (180,000 exons + 551 miRNA exons represented) allow for a broad range of scientific questions to be addressed.
Quality Control
ATLAS Biolabs is certified according to the international standards ISO 9001:2008 and ISO 13485. Our production processes are subject to rigorous quality control at all steps:
- Quality and quantity of each DNA sample sent to ATLAS Biolabs will be determined by agarose gel analysis and by photometric analysis. Samples which do not pass QC will not be processed.
- Numerous control steps are executed during library preparation, e.g. QC of successful DNA fragmentation, QC of successful linker ligation, etc.
- Enrichment of the genomic sequences of interest is assessed by quantitative PCR of control loci.
- All quality assurance procedures are electronically documented and available for our customers on demand.